BNZNV - NO. 16 MECHANICAL PUMP OIL
- MSDS: BNZNV
- Manufacturer: EDWARDS HIGH VACUUM INTERNATIONAL
- Product Name: NO. 16 MECHANICAL PUMP OIL
- National Stock Number: 9150-00F025284
Product Identification
Product ID:NO. 16 MECHANICAL PUMP OIL
MSDS Date:01/01/1989
FSC:9150
NIIN:00F025284
MSDS Number: BNZNV
Responsible Party
WILMINGTON, MA 01887
US
Emergency Phone: (508) 658-5410
Info Phone: (508) 658-5410
Cage: 21268
Contractor
Telephone: (508) 658-5410
Cage: 1Z295
Ingredients
MINERAL OIL, PETROLEUM EXTRACTS, HEAVY PARAFFINIC
CAS: 64742-04-7
RTECS: PY8042500
Fraction By Weight: <80%
RESIDUAL OILS, SOLVENT-REFINED
Fraction By Weight: <21%
Hazards
LD50 LC50 Mixture:ORAL (RAT) LD50: >5 MLS/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION & CONJUNCTIVA. SKIN:
KERATOSIS & DERMATITIS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: IRRITATION & CONJUNCTIVA. SKIN: KERATOSIS
& DERMATITIS.
Fire Fighting
Flash Point Method:PMCC
Flash Point:460F
Extinguishing Media:FOAM, DRY POWDER, CO2, HALON
Fire Fighting Procedures:DON'T USE WATER JETS.
Accidental Release
Spill Release Procedures:PREVENT THE SPREAD OF PRODUCT & ESPECIALLY ITS
ENTRY INTO DRAINS/WATERCOURSES BY THE USE OF SAND, EARTH OR OTHER
ABSORBENT MATERIAL. W/OUT OUT RISK RECOVER BULK PRODUCT. RESIDUE
SPILLS: ABSORB/REMOVE CONTAMINATED ABSORBENT TO SAFE PLACE FOR
DISPOSAL.
Handling
Handling and Storage Precautions:STORE UNDER COVER AWAY FROM DIRECT
HEAT & HIGH TEMPS. CONTAINERS SHOULD BE KEPT SEALED WHEN NOT IN
USE.
Other Precautions:AVOID INHALATION OF VAPORS, OILS MISTS, FUMES &
CONTACT W/SKIN.
Exposure Controls
Protective Gloves:PVC
Other Protective Equipment:OVERALLS
Work Hygienic Practices:OVERALLS SHOULD BE LAUNDERED REGULARLY. USE
GOOD STANDARDS/PERSONAL HYGIENE.
Supplemental Safety and Health
Chemical Properties
Appearance and Odor:OILY NEUTRAL/PALE AMBER LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:EXTREMES OF TEMPS & SOURCES OF IGNITION
Hazardous Decomposition Products:HYDROCARBONS, OXIDES OF CARBON, TRACES
OF OXIDES OF NITROGEN & SULPHUR
Disposal
Waste Disposal Methods:CONTAMINATED BULK & ABSORBENT SHOULD BE DISPOSED
OF BY LICENSED WASTE CONTRACTOR. INCINERATION IS PREFERABLE TO
LANDFILL. DON'T ALLOW TO ENTER DRAINAGE SYSTEMS OR
RIVERS/WATERWAYS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.